NEXT GENERATION FIRE ALARM CONTROL PANEL

16 SLCs – 3,200 intelligent addressable devices

􀁸 CCCF listed
􀁸 UL listed

The NX30 is an intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NX30 is ideally suited for these applications because it features a modular design that is configured per project requirements.

Information is a critical to fire evacuation personnel, and the NX30’s large colorful 7’’ Thin Film Transistor (TFT) Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situation, fire progression, and evacuation details.

Field Programming Options

Auto program is a timesaving feature. The FACP “learns” what devices are physically connected and automatically loads them in the program with default values for all parameters.
Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installation, even if only a portion of the detectors are installed.

Keypad Program Edit. The NX30, like all NOTIFIER intelligent panels, has the exclusive feature of program creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NX30 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per point segments, while the NX30 simultaneously monitors other (already installed) points for alarm conditions.

VeriFire® Tools
VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Windows® based and provides technologically advanced
capabilities to aid the installer. The installer may create the entire program for the NX30 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel.

Primary Input Power:
– AMPS-24E 220 VAC (+10%, -15%), 50HZ, 2A maximum

DC Output:
– One 24 VDC/3A resettable
– One 24 VDC/3A non-resettable
– One 5 VDC/3A for micro printer

5%~95% (noncondensing). However, the useful life of the system’s standby batteries and the electronic components may be adversely affected by extreme temperatures ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15~27deg. C.

 

System Capacity
􀁸 Intelligent Signaling Line Circuits…………………………………………………1 expandable to 16
􀁸 Intelligent detectors and addressable modules…………………………………………200 per loop
􀁸 Network nodes………………………………………………………………………………….64 nodes
􀁸 Programmable software zones……..1,000 Logic Zone, 100 Trouble Zone, 1,000 General Zone
􀁸 ACS annunciators per NX30……………………………………….4 x 32 buttons and 4 x 64 LEDs

Để đặt mua sản phẩm: Tủ trung tâm báo cháy địa chỉ thông minh NX30

Quý khách hàng vui lòng điền đầy đủ thông tin theo mẫu bên dưới, chúng tôi sẽ liên hệ lại với quý khách trong vòng 24h.

Main System Components

CPU-30-E: NX30 Primary Central Processing Unit (CPU) with aluminum housing and is installed in the NX30 back box.

GUI-30-E: Graphic User Interface. GUI-30 ships with display/keypad installed; includes a colorful 7’’ TFT LCD display, programming and control keypad. Non-English versions are available: GUI-30-SC (Simplified  Chinese), GUI-30-TC (Traditional Chinese).

LCM-30-E: Loop Control Module. Provides up to 2 SLC. NX30 supports up to eight LCM-30s for a total of sixteen SLCs.

AMPS-24E: Power Supply. One required for each NX30. Addressable power supply and battery charger with two 24 VDC outputs.   
Addressable by any CLIP mode FACP. Charges 12 to 75 AH batteries @3A output. Primary input power for panel.  

NCM-W-30-E: Standard Network Communications Module. Wire versions.

ACM-30-E: NX30 ACS annunciator – up to 32 settable buttons with 2 LEDs each. LED (upper) indicating controller state, red for activated and yellow for trouble. LED (down) indicating supervisor status, red for activated and yellow for trouble.

UPRT-30: Micro Printer. Need to order SBB-30/P to install micro printer.

BMP-30: Blank module for unused ACM positions.

SBB-30-E: Standard Back Box with main board inside and without micro printer installation hole.
Back box with micro printer installation hole optional: SBB-30/P-E

SAMPLE SYSTEM: Four-loop NX30 with display: CPU-30-E, GUI-30-E, AMPS-24E, two LCM-30-E, SBB-30-E, four BMP-30, and batteries.

LCD-200-E: Floor display annunciator. LCD screen display supports max 250 fire events and 750 trouble events.

POM-30-E: Direct control module with 8 lines. Each ACM-30-E can control max 2 POM-30-E modules and each NX30 panel can have max 8 POM-30-E modules (Optional per local regulations).

FM12-20: 12V-20AH battery. Each NX30 panel need at least two 12V-20AH batteries, suggest to purchase locally according to requirements.